Product Description
  • Flat, soft teat – like mom’s breast when breastfeeding
  • For an easy switch between breast and bottle
  • Reduces colic and discomfort - less colic confirmed by 80% of mothers2
  • Made with bio-circular materials3
  • With unique self-sterilizing function – easy & fast in only 3 min
  • Easy to fill, use & clean



1. DUST CAP
Spill-proof; doubles as measuring cup

2. SKINSOFTTM SILICONE TEAT
Unique flat symmetric shape – like mom’s breast when breastfeeding. Silky soft silicone surface - for a familiar feeling. 94% of babies accept our bottle teat1

3. WIDE OPENINGS
Easy to fill, use & clean

4. VENTED BASE
Smooth flow prevents baby from swallowing air; reduces air colic & discomfort

MADE WITH BIO-CIRCULAR MATERIALS
All parts except the teat are made from polypropylene linked to bio-circular feedstocks according to the mass balance approach certified by ISCC PLUS.

This product meets the requirements of European Standard EN 14350:2020.
Bottle teat fits all MAM wide neck bottles and the Trainer.

1Market research 2010-2020, tested with 1,572 babies.  
2Field study, Austria 2011, tested with 73 mothers of babies with colic / Market research, USA 2010, tested with 35 mothers of babies with colic.

Quality & Safety
94% nipple acceptance: easily accepted by babies – for a familiar feeling

94% nipple acceptance: easily accepted by babies – for a familiar feeling

All MAM products are made from materials free of BPA and BPS

All MAM products are made from materials free of BPA and BPS

MAM SkinSoft™ Silicone: easily accepted by babies - for a familiar feeling

MAM SkinSoft™ Silicone: easily accepted by babies - for a familiar feeling

 This product has a self-sterilizing function - ideal for on the go

This product has a self-sterilizing function - ideal for on the go

For babies from 2 months

For babies from 2 months

Flow rate 2: perfect for breast milk and formula

Flow rate 2: perfect for breast milk and formula

This product is made in Europe

This product is made in Europe

¹ Market research 2009-2023, tested with 1,808 babies.

Awards & Certificates
DEVELOPED WITH MEDICAL EXPERTS

DEVELOPED WITH MEDICAL EXPERTS

Teamwork with medical experts for maximum safety.
Only after approval by medical experts is a MAM innovation ready for baby life.
HONORED WITH THE EU PRODUCT SAFETY AWARD 2019

HONORED WITH THE EU PRODUCT SAFETY AWARD 2019

Your baby means everything to you and that is why we do everything to offer you only extra-safe products. For this reason, many MAM innovations are researched and developed in partnership with medical professionals. In addition, our internal safety standards and testing criteria go well beyond the norms.
These efforts have now been formally recognised by the European Commission, which presented MAM with the prestigious EU PRODUCT SAFETY AWARD 2019. Because for us, there is nothing more worthwhile than supporting the healthy development of babies and making parents’ daily life easier.
FAQ

For hygiene reasons, the nipples should be replaced at regular intervals. Simply check the nipple each time you are about to use the bottle – especially when baby already has teeth – and replace it when the first signs of damage or weak points become apparent.

The MAM nipple is easily accepted by 94%* of babies thanks to its SkinSoft™ silicone surface and its unique flat shape, which feel so familiar to babies. This facilitates a switching between breast- and bottlefeeding.

(*Market research 2009-2023, tested with 1,808 babies)

Bottle nipples are simply rinsed with water and mild cleaning agent or cleaned in the upper compartment of the dishwasher.
The nipple is sterilized before it is first used and then at regular intervals.

Self-Sterilising

  • The self-sterilising function of the Easy Start Bottle is proven to be effective for killing common household germs and bacteria. This method is completely sufficient and safe. For the best results, please follow all instructions carefully and use only as directed.
  • Always thoroughly clean individual bottle parts before beginning this process!
  • After cleaning, assemble bottle parts as follows: base with with silicone valve, teat with screw ring, bottle body and protective cap.

aHR0cHM6Ly93d3cubWFtYmFieS5jb20vbWVkaWEvOWYvNmEvYTIvMTcyNzY5ODQ0NC9NQU1fZXNhY19zZWxmX3N0ZXJpbGlzaW5nXzNfc3RlcHNfMTIwMHg2MDBweC5qcGc

Step 1: Measure 20 ml of cool water using the bottle cap. Fill the base with silicone valve with 20 ml of cool water.

Step 2: Place the screw ring with teat in the bottle base. Place the bottle body on it. Screw in JUST SLIGHTLY to avoid pouring out hot water when removing the bottle from microwave. DO NOT SCREW DOWN FULLY.

Step 3: Place the protective cap on top. Set the microwave timer according to the number of bottles being simultaneously cleaned. Set microwave from 500 to 1000 Watts.

aHR0cHM6Ly93d3cubWFtYmFieS5jb20vbWVkaWEvMWUvMmIvNTUvMTcyNzY4MTAwNC9NQU1fdGFiZWxsZW5fc3RlcmlsaXNpZXJ6ZWl0LWVhc3lfc3RhcnRfRU4ucG5n

  • After self-sterilising allow bottle to cool down before removing from microwave.
  • Recommended cooling time at least 10 minutes with opened microwave door. Be careful to hold the base and keep the bottle straight when removing from the microwave to avoid spilling any left over hot water.
  • After the process is complete, the Easy Start bottle remains disinfected for up to 48 hours after self-sterilising in the microwave, provided that it remains assembled as shown in Step 3.
  • For immediate usage: Pour away the leftover water from the base. Allow bottle parts to dry.
  • Always store bottle assembled.

IMPORTANT FACTS - For correct microwave sterilisation
  • Follow the instructions in the user manual of your microwave or multifunctional device.
  • Ensure that all parts of the self-sterilising bottle and microwave (including waveguide cover and turntable) are COMPLETELY clean and free from dirt, food residue, fat or oil splashes. If not this could lead to the product melting, the microwave sparking or the waveguide-cover burning!
  • The Easy Start Anti-Colic bottle should only be placed on solid and flat surfaces.
  • Do not put the Easy Start Anti-Colic bottle in the center of the turntable as this could result in an uneven heat distribution.
  • Do not leave your microwave unattended during the sterilising process.
  • Never place the device in the microwave without water.
  • Stop the microwaving process immediately if all the water has been vaporised!
  • Filling the base with too much or not enough water can damage the bottle.
  • Always set the microwave to the correct power and time.
  • If using a combination microwave oven, ensure that the Easy Start Anti-Colic bottle is not exposed to the heat of the grill because this will damage it.
  • TAKE CARE when handling recently disinfected items: they may still be hot.
  • Wash hands before touching disinfected items.
  • Be careful to hold the base and keep holding the bottle up straight when removing from the microwave to avoid spilling any leftover hot water.
  • Do not wash the Easy Start Anti-Colic bottle after disinfection.
  • Do not touch the teat after disinfection. Handle teat by using the screw ring.

RECOMMENDED MAM PRODUCTS FOR YOU

NEW

MAM Supreme Soother 2-6 months, set of 2

For healthy oral development and ideal for sensitive skin

€11.99

Starter Cup Forest 150ml - Drinking Cup

Baby's first cup. Extra light & small

€9.99

MAM Comfort 3-12 Silicone Pacifier

Especially small & lightweight 100% silicone pacifier

€10.99

Massaging Brush for baby's oral care

Cleans and massages sensitive gums & first teeth

€4.99

Learn to Brush Set - Baby Toothbrushes

Set with MAM Training Brush & Baby’s Brush

€8.79

Trainer+ Night

With glowing handle for easy night-time drinking

€11.59

Max the Frog - Latex Developmental Toy

100% natural rubber – extra soft and safe

€9.99